Skip to product information
1 of 7

FXN Sticker for Small Electrical Enclosures

FXN Sticker for Small Electrical Enclosures

Regular price $39.99 USD
Regular price Sale price $39.99 USD
Sale Sold out
Shipping calculated at checkout.
Size
Quantity

FXN Sticker is a passive, heat-activated, microcapsule-based fire suppression sticker designed to provide supplemental localized protection inside compatible electrical and electronic enclosures. Mounted on the enclosure ceiling, its microcapsules release electrically non-conductive FK-5-1-12 clean agent when the sticker reaches its activation temperature. No sensors, batteries, external power or control wiring are required.

Evaluate FXN Sticker for control panels, distribution boards, automation cabinets, network and telecom cabinets, OEM machine enclosures and similar enclosed applications. Choose a fixed model by enclosure volume, or the FXN-SA4 professional sheet, cut into sizes S1 to S65, when you service a mix of enclosure sizes. It adds a layer of localized suppression but does not prevent electrical faults or replace required fire and electrical safety systems.

Choose Your FXN Sticker Model

FXN-S20 red fire suppression sticker, 3.94 x 1.57 x 0.04 in, held in hand for size reference

FXN-S20 | 3.94 × 1.57 in

$39.99

Sizing reference: up to 0.7 ft³ (20 L) in suitable enclosures.

Shop FXN-S20

FXN-S30 square fire suppression sticker, 3.94 x 3.94 x 0.04 in, dimensions reference

FXN-S30 | 3.94 × 3.94 in

$99.99

Sizing reference: up to 1.0 ft³ (30 L) in suitable enclosures.

Shop FXN-S30

FXN-S50 fire suppression sticker, 5.91 x 3.94 x 0.04 in, held in hand for size reference

FXN-S50 | 5.91 × 3.94 in

$149.99

Sizing reference: up to 1.8 ft³ (50 L) in suitable enclosures.

Shop FXN-S50

FXN-S65 fire suppression sticker, 7.87 x 3.94 x 0.04 in, held in hand for size reference

FXN-S65 | 7.87 × 3.94 in

$199.99

Sizing reference: up to 2.3 ft³ (65 L) in suitable enclosures.

Shop FXN-S65

FXN-SA4 professional sticker sheet cutting chart showing S20, S30, S50 and S65 cut sizes and covered enclosure volumes

FXN-SA4 | 7.87 × 11.81 in professional sheet

$279.99

Professional sheet for electrical distributors and contractors. Cut into sticker sizes S1 to S65 (S1: 0.75 x 0.75 in nominal; S20 to S65 along the printed grid). Cut dimensions, placement, and required coverage must follow FireXNull's applicable product specifications and installation guidelines.

Shop FXN-SA4Request Contractor or Distributor Pricing

Model-specific sizing references are not guaranteed coverage or extinguishment performance. Actual suitability depends on enclosure geometry, ventilation, leakage, component layout and potential ignition locations. If an enclosure falls between two sizes, select the next larger model. Prices are current Shopify listings and may change; taxes and shipping are calculated at checkout.

Request an OEM / Project QuoteRequest an Evaluation Sample

Why Choose Passive FXN Sticker?

  • Automatically heat activated: microcapsules are designed to release FK-5-1-12 at 248°F ± 9°F (120°C ± 5°C).
  • No external electrical connections: operates without power, sensing electronics or manual triggering.
  • Fast retrofit: adhesive-backed, non-pressurized format for new equipment and existing enclosures during routine service.
  • Clean agent: FK-5-1-12 is electrically non-conductive and the agent itself leaves no residue, which helps limit cleanup and downtime.
  • Class A, B, and C fire hazards: designed for supplemental, localized suppression in compatible applications; FK-5-1-12 is a clean agent recognized in NFPA 2001.
  • No routine servicing required: operates automatically without external power, wiring, refilling, or recharging. Periodic visual inspection and replacement according to product instructions are recommended.
  • Supplemental protection: complements proper equipment design, electrical protection, inspections and code-required fire safety systems.

FXN Sticker Technical Specifications

Property Specification / Guidance
Activation temperature 248°F ± 9°F (120°C ± 5°C), at the sticker
Models and size FXN-S20 3.94 × 1.57 in (100 × 40 mm); FXN-S30 3.94 × 3.94 in (100 × 100 mm); FXN-S50 5.91 × 3.94 in (150 × 100 mm); FXN-S65 7.87 × 3.94 in (200 × 100 mm); FXN-SA4 7.87 × 11.81 in (200 × 300 mm), 5.64 oz (160 g)
Thickness 0.04-0.08 in (1-2 mm) nominal
Active agent Microcapsule-encapsulated FK-5-1-12, electrically non-conductive
Operating environment Compatible enclosed electrical/electronic equipment; sustained ambient at or below 149°F (65°C); 80% RH or less, non-condensing
Installation location Top interior surface (ceiling) of the enclosure only
Device type Non-pressurized, adhesive-backed, single-use; replace after activation
Color Red
Care and replacement No routine servicing or recharging required. Visually inspect periodically during equipment service. Recommended replacement five years after installation under specified conditions, or sooner if activated, damaged, loose or obstructed.

Reference specifications are provided to support preliminary product selection. For controlled technical documents and application-specific requirements, request the current approved TDS, SDS and installation instructions from FireXNull.

Installation and Electrical Safety

Installation should be performed by qualified personnel. Before opening electrical equipment, turn off and verify it is de-energized, and follow applicable lockout/tagout and electrical safe-work procedures. Attach the sticker to a clean, dry, flat top interior surface with unobstructed exposure to rising heat, and press the entire adhesive footprint firmly. Keep the sticker clear of conductors, terminals and moving parts, and preserve required electrical and service clearances. Do not bend, fold, puncture, cover or paint the sticker. Avoid wet or condensing conditions and consult FireXNull for vented or forced-air cabinets.

FXN Sticker is not an electrical insulator, fault-repair product or substitute for required fire protection. Record the installation date and use the instructions applicable to the selected model.

How Do I Size FXN Sticker for Larger Enclosures?

Select by internal enclosure volume using the sizing references above. For enclosures larger than 2.3 ft³ (65 L), compartmented cabinets, or equipment with vents or forced cooling, request a sizing review. Larger cabinets may be better served by FXN Rope, and individual terminations by FXN Tape. For indoor outlet and switch boxes, use the dedicated FXN-S1.

Where Can FXN Sticker Be Evaluated?

Use in energy-storage installations, if considered, is limited to suitable electrical and control enclosures within a broader safety design. FXN Sticker is not claimed to stop battery thermal runaway or propagation.

Request Technical Data and Safety Documents

Request current approved versions of the FXN Sticker Technical Data Sheet (TDS), Safety Data Sheet (SDS) and installation guidance. Include the model, enclosure dimensions, ventilation conditions and the application you are evaluating.

Request FXN Sticker TDSRequest FXN Sticker SDS

Related Guides

Frequently Asked Questions

Which FXN Sticker model do I need?

Choose by internal enclosure volume: FXN-S20 up to 0.7 ft³ (20 L), FXN-S30 up to 1.0 ft³ (30 L), FXN-S50 up to 1.8 ft³ (50 L) and FXN-S65 up to 2.3 ft³ (65 L). If the volume falls between sizes, select the next larger model.

Can FXN-SA4 be cut to any size?

No. Cut FXN-SA4 only into the defined sticker sizes S1 to S65 (S1: 0.75 x 0.75 in nominal; S20, S30, S50 and S65 along the printed grid), following FireXNull's cut and placement guidelines. Do not cut the fixed-size models or make arbitrary modifications.

What temperature activates FXN Sticker?

Its specified activation temperature is 248°F ± 9°F (120°C ± 5°C) at the sticker, the same as FXN Tape and different from FXN Rope.

Can I use more than one sticker in a large cabinet?

Larger or compartmented enclosures may need more than one unit or a different format. Ask FireXNull for an application-specific sizing review before installing.

Is FXN Sticker UL Listed?

No. FXN Sticker is not UL Listed as a fire suppression product. It is supplemental localized protection and does not replace code-required fire protection or electrical safety systems.

Does FXN Sticker leave residue?

The FK-5-1-12 clean agent itself leaves no residue. Replace the sticker after any activation and inspect the equipment before returning it to service.

Find the Right Configuration for Your Equipment

Shop FXN-S30Shop FXN-SA4

Request a Quote / Sizing ReviewRequest TDSRequest SDS

FireXNull products are supplemental localized fire suppression layers. Application suitability and performance depend on equipment and use conditions. Do not use as a substitute for code-required protection or electrical maintenance.

View full details

FIREXNULL / FXN STICKER / ENCLOSURE SUPPRESSION

Passive fire suppression for electrical enclosures

FXN Sticker mounts on the top interior surface of a compatible electrical enclosure, providing localized, heat-activated fire suppression without sensors, wiring or external power. Choose S20 to S65 by enclosure volume, or cut the FXN-SA4 professional sheet into sizes S1 to S65.

No powerPassive heat response
No sensorsAutomatic activation
LocalizedApplication-specific placement
SupplementalComplements required fire protection

01 / APPLICATIONS

Where to evaluate it

  • Control panels and distribution boards
  • Industrial automation and MCC enclosures
  • Network, telecom and electronics cabinets

02 / PRODUCT FACTS

At a glance

  • 248°F nominal activation
  • Sized by enclosure volume, S20 to S65
  • SA4 professional sheet, cut into sizes S1 to S65
  • Electrically non-conductive clean agent

03 / INSTALLATION & EVALUATION

Before you install or integrate

  1. De-energize and verify the electrical equipment is safe to work on.
  2. Select the sticker size for the enclosed volume and place on a clean, dry upper interior surface.
  3. Ensure full adhesion and clearance, record the installation date, then close the enclosure.
Request technical data sheet →

04 / FREQUENTLY ASKED QUESTIONS

What to know

Where does FXN Sticker go?

Mount the selected model on the top interior surface of a compatible enclosed cabinet, above likely ignition sources, without interfering with components or clearances.

Does it require power?

No. The microcapsule-based device activates in response to heat at the material.

Can it replace code-required protection?

No. FXN Sticker provides supplemental localized protection, not a substitute for electrical codes or required systems.

When is replacement recommended?

The technical data sheet recommends replacement five years after installation under specified conditions, and sooner after activation or damage.

FireXNull products are supplemental, application-specific localized fire suppression solutions and do not replace code-required fire detection, fire protection, or safe electrical installation practices. Refer to the product TDS and SDS.