Skip to product information
1 of 5

FXN Tape for Wire Connections

FXN Tape for Wire Connections

Regular price $54.99 USD
Regular price Sale price $54.99 USD
Sale Sold out
Shipping calculated at checkout.
Suitable space
Size
Quantity

View UL material record E543590
Recognition applies to the component material used in FXN Tape, not the finished fire suppression product.

FXN Tape is a passive, heat-activated, microcapsule-based fire suppression tape designed to provide supplemental localized protection at wire connections, terminals and bus connectors inside electrical equipment. Its microcapsules contain electrically non-conductive FK-5-1-12 clean agent. The tape activates without sensors, batteries, external power or control wiring.

Evaluate FXN Tape where heat at a specific connection is the concern: terminal blocks, wire junctions, cable lugs and panel connections in control cabinets, distribution enclosures and OEM assemblies. It acts at the connection itself but does not prevent electrical faults, replace proper torque and termination practice, or replace required fire and electrical safety systems.

Choose Your FXN Tape Model

FXN-T25 | 1.0 in × 3.3 ft roll

$54.99

One 1.0 in × 3.3 ft (25 mm × 1 m) roll with pressure-sensitive adhesive backing, for wrapping eligible wire connections and terminals.

Shop FXN-T25

Performance depends on proper installation, full coverage of the connection and use within specified conditions. Prices are current Shopify listings and may change; taxes and shipping are calculated at checkout.

Request a Volume / Project QuoteRequest an Evaluation Sample

Why Choose Passive FXN Tape?

  • Protection at the connection: applied directly where loose or degraded terminations can overheat.
  • Automatically heat activated: microcapsules are designed to release FK-5-1-12 at 248°F ± 9°F (120°C ± 5°C).
  • No external electrical connections: operates without power, sensing electronics or manual triggering.
  • Clean agent: FK-5-1-12 is electrically non-conductive and the agent itself leaves no residue, which helps limit cleanup and downtime.
  • UL Recognized Component Material: FXN Tape incorporates FXN-15L acrylate sheet, UL File E543590, HB flammability classification.
  • Class A, B, and C fire hazards: designed for supplemental, localized suppression in compatible applications; FK-5-1-12 is a clean agent recognized in NFPA 2001.
  • No routine servicing required: operates automatically without external power, wiring, refilling, or recharging. Periodic visual inspection and replacement according to product instructions are recommended.
  • Supplemental protection: complements proper terminations, electrical protection, inspections and code-required fire safety systems.

FXN Tape Technical Specifications

Property Specification / Guidance
Activation temperature 248°F ± 9°F (120°C ± 5°C), at the tape
Size (FXN-T25) 1.0 in × 3.3 ft (25 mm × 1 m) roll
Thickness 0.016-0.017 in (0.40-0.44 mm)
Active agent Microcapsule-encapsulated FK-5-1-12, electrically non-conductive
Adhesive Pressure-sensitive backing
Material recognition UL Recognized Component Material: FXN-15L acrylate sheet, UL File E543590, category QMFZ2, HB flammability classification. Recognition applies to the component material, not the finished fire suppression product.
Operating environment Enclosed or semi-enclosed electrical equipment; sustained ambient at or below 149°F (65°C); 80% RH or less, non-condensing
Device type Non-pressurized, single-use; replace after activation. Not electrical insulation tape.
Care and replacement No routine servicing or recharging required. Visually inspect periodically during equipment service. Recommended replacement five years after installation under specified conditions, or sooner if activated, damaged, loose or lifted.

Reference specifications are provided to support preliminary product selection. For controlled technical documents and application-specific requirements, request the current approved TDS, SDS and installation instructions from FireXNull.

Installation and Electrical Safety

Installation should be performed by qualified personnel. Turn off and verify the equipment is de-energized, and follow applicable lockout/tagout and electrical safe-work procedures. Confirm the connection is correctly made, torqued and insulated before applying FXN Tape. Apply the tape to clean, dry connections so it covers the connection fully and adheres without lifted edges, following the installation instructions. Keep required electrical clearances, labels and inspection points accessible.

FXN Tape is not electrical insulation, a splice or a fault-repair product. Never apply it to energized conductors, and do not use it to cover a damaged or overheating connection. Correct the electrical problem first.

Where Can FXN Tape Be Evaluated?

Use in energy-storage installations, if considered, is limited to suitable electrical connections within a broader safety design. FXN Tape is not claimed to stop battery thermal runaway or propagation.

Request Technical Data and Safety Documents

Request current approved versions of the FXN Tape Technical Data Sheet (TDS), Safety Data Sheet (SDS) and installation guidance. Include the connection type, conductor size, enclosure conditions and the application you are evaluating.

Request FXN Tape TDSRequest FXN Tape SDS

Related Guides

Frequently Asked Questions

What temperature activates FXN Tape?

Its specified activation temperature is 248°F ± 9°F (120°C ± 5°C) at the tape, the same as FXN Sticker and different from FXN Rope.

When should I choose FXN Tape instead of FXN Sticker or FXN Rope?

Choose FXN Tape to protect individual connections and terminals. Choose FXN Sticker or FXN Rope for enclosure-level protection. Many enclosures use tape on critical terminations together with an enclosure-level product.

Is FXN Tape UL Listed?

No. FXN Tape incorporates UL Recognized Component Material (FXN-15L acrylate sheet, UL File E543590, HB flammability classification). Recognition applies to the component material, not the finished fire suppression product.

Does FXN Tape leave residue?

The FK-5-1-12 clean agent itself leaves no residue. Replace the tape after any activation and have the connection inspected before returning equipment to service.

Can I buy FXN Tape in larger quantities?

Yes. For contractor, OEM or project volumes, request a volume quote.

Find the Right Configuration for Your Equipment

Shop FXN-T25

Request an Application ReviewRequest TDSRequest SDS

FireXNull products are supplemental localized fire suppression layers. Application suitability and performance depend on equipment and use conditions. Do not use as a substitute for code-required protection or electrical maintenance.

View full details

FIREXNULL / FXN TAPE / CONNECTION PROTECTION

Localized suppression at electrical connection points

FXN Tape is an adhesive-backed, microcapsule-based suppression format for wire junctions, terminals and other eligible connection points inside electrical equipment.

No powerPassive heat response
No sensorsAutomatic activation
LocalizedApplication-specific placement
SupplementalComplements required fire protection

01 / APPLICATIONS

Where to evaluate it

  • Wire junctions and terminal blocks
  • Bus connectors and panel connections
  • OEM electrical assemblies and machinery

02 / PRODUCT FACTS

At a glance

  • 248°F nominal activation
  • Trim-to-length adhesive-backed tape
  • Localized application at connections

03 / INSTALLATION & EVALUATION

Before you install or integrate

  1. Disconnect and verify power is off before working around electrical conductors.
  2. Apply to clean, dry eligible connections, following the product instructions and applicable electrical installation standards.
  3. Check adhesion and clearances; retain proper insulation and record the installation date.
Request technical data sheet →

04 / FREQUENTLY ASKED QUESTIONS

What to know

Is FXN Tape electrical insulation tape?

No. It is a supplemental fire suppression product and does not replace required electrical insulation.

Where is it designed to be used?

At eligible wire connections, terminals and bus connectors in enclosed or semi-enclosed electrical equipment.

Is power required for activation?

No. Heat at the tape activates the microcapsule-based agent release.

Can I install it on energized connections?

No. Disconnect and verify power is off before installation.

FireXNull products are supplemental, application-specific localized fire suppression solutions and do not replace code-required fire detection, fire protection, or safe electrical installation practices. Refer to the product TDS and SDS.