Skip to product information
1 of 9

FXN Rope for Electrical Enclosures

FXN Rope for Electrical Enclosures

Regular price $249.99 USD
Regular price Sale price $249.99 USD
Sale Sold out
Shipping calculated at checkout.
Size
Quantity

FXN Rope, sometimes called a fire rope or fire extinguisher rope, is a passive, heat-activated, microcapsule-based fire suppression rope designed to provide supplemental localized protection inside compatible electrical and electronic enclosures. Its microcapsules contain electrically non-conductive FK-5-1-12 clean agent. The product activates without sensors, batteries, external power, or control wiring.

Evaluate FXN Rope for industrial control cabinets, electrical distribution enclosures, compatible data center equipment, OEM machine control compartments, and similar enclosed applications. It adds a layer of localized suppression but does not prevent electrical faults or replace required fire and electrical safety systems.

Choose Your FXN Rope Model

FXN-R30 3.3-foot braided heat-activated fire suppression rope with two finished ends

FXN-R30 | 3.3 ft

$249.99

Manufacturer sizing reference: up to 1.0 ft³ (30 L) in suitable enclosures.

Shop FXN-R30

FXN-R100 longer braided rope length and dimensions reference for electrical cabinets

FXN-R100 | 7.55 ft

$489.99

Manufacturer sizing reference: 2.5–3.5 ft³ (65–100 L) in suitable enclosures.

Shop FXN-R100

Model-specific sizing references are not guaranteed coverage or extinguishment performance. Actual suitability depends on enclosure geometry, ventilation, leakage, component layout and potential ignition locations. Prices are current Shopify listings and may change; taxes and shipping are calculated at checkout.

Request an OEM / Project QuoteRequest an Evaluation Sample

What Is a Fire Rope?

A fire rope, also called a fire extinguisher rope or fire suppression rope, is a flexible cord that carries a fire suppression agent and releases it automatically when it gets hot. FXN Rope uses microencapsulated FK-5-1-12 clean agent and activates at 428°F ± 9°F (220°C ± 5°C) at the rope, so it can follow wiring and component runs inside compatible enclosures where a single compact device would not reach. Actual suppression time depends on flame size and enclosure volume.

Why Choose Passive FXN Rope?

  • Automatically heat activated: responsive microcapsules are designed to release FK-5-1-12 at their activation temperature.
  • No external electrical connections: operates without power, sensing electronics or manual triggering.
  • Flexible format: suitable for planned positioning around different potential ignition areas inside compatible enclosures, while maintaining clearances.
  • Residue-Free Clean Agent: FK-5-1-12 itself leaves no residue; minor rope material residue may remain after activation.
  • Class A, B, and C fire hazards: designed for supplemental, localized suppression in compatible applications; FK-5-1-12 is a clean agent recognized in NFPA 2001.
  • No routine servicing required: operates automatically without external power, wiring, refilling, or recharging. Periodic visual inspection and replacement according to product instructions are recommended.
  • Supplemental protection: complements proper equipment design, electrical protection, inspections and code-required fire safety systems.

FXN Rope Technical Specifications

Property Specification / Guidance
Activation temperature 428°F ± 9°F (220°C ± 5°C), at the rope
Diameter 0.20–0.28 in (5–7 mm)
Active agent Microcapsule-encapsulated FK-5-1-12
Operating environment Compatible enclosed electrical/electronic equipment; sustained ambient at or below 149°F (65°C); non-condensing
Installation orientation Horizontal, in the upper interior of the enclosure, subject to mounting guidance
Device type Non-pressurized, single-use; replace after activation
Care and replacement No routine servicing or recharging required. Visually inspect at least annually. Recommended replacement after five years of installation under specified conditions; verify the current approved instructions and installation record.

Reference specifications are provided to support preliminary product selection. For controlled technical documents and application-specific requirements, request the current approved TDS, SDS and installation instructions from FireXNull.

Installation and Electrical Safety

Installation should be performed by qualified personnel. Before opening electrical equipment, turn off and verify it is de-energized, and follow applicable lockout/tagout and electrical safe-work procedures. Secure the full, uncut rope in a suitable upper-interior location with approved mounting hardware and appropriate spacing. Keep the rope and all supports clear of bare conductors, terminals and busbars; preserve required electrical and service clearances. Do not crush, sharply kink, cover or obstruct the rope. Avoid wet or condensing conditions and consult FireXNull for ventilated cabinets.

FXN Rope is not an electrical insulator, fault-repair product or substitute for required fire protection. Always use the instructions applicable to the selected model and enclosure.

Can Multiple FXN Rope Units Be Connected for Larger Enclosures?

Yes, for selected applications. FireXNull confirms that more than one complete FXN Rope unit may be combined when the units are connected at one end only. Keep each factory-finished rope intact. The one-end connection arrangement, approved mounting/connection hardware, electrical clearances, routing, and number of units must be reviewed with FireXNull for the specific enclosure before installation. Do not cut, splice, crush, or otherwise alter the rope bodies.

Joining units does not mean their individual enclosure-sizing references can simply be added together, nor does it guarantee whole-enclosure protection. Contact FireXNull for a larger enclosure or multi-rope application review.

Where Can FXN Rope Be Evaluated?

Use in energy-storage installations, if considered, is limited to suitable electrical and control enclosures within a broader safety design. FXN Rope is not claimed to stop battery thermal runaway or propagation.

Request Technical Data and Safety Documents

Request current approved versions of the FXN Rope Technical Data Sheet (TDS), Safety Data Sheet (SDS), and installation guidance. Include FXN-R30 or FXN-R100, enclosure dimensions, ventilation conditions, and the application you are evaluating.

Request FXN Rope TDSRequest FXN Rope SDS

Frequently Asked Questions

Does FXN Rope require wiring, batteries, or sensors?

No. FXN Rope is a passive, heat-activated product. It does not need electrical power or sensing electronics for activation.

What temperature activates FXN Rope?

Its specified activation temperature is 428°F ± 9°F (220°C ± 5°C) at the rope, distinct from FXN Sticker and FXN Tape activation temperatures.

Can I cut FXN Rope to fit an enclosure?

No. Do not cut or modify a finished rope. Select an appropriate model or contact FireXNull for OEM and larger-enclosure options.

Can I use two or more ropes in one cabinet?

Multiple complete ropes may be connected at one end for selected larger enclosures. Ask FireXNull for the approved arrangement and application-specific assessment; do not improvise a connector.

Is FXN Rope UL Listed or a replacement for required suppression?

No. FXN Rope has no UL fire-suppression listing or rating. It provides supplemental, localized protection and does not replace code-required detection, suppression, or electrical safety measures.

Does FXN Rope leave residue?

FK-5-1-12 clean agent itself leaves no residue. Some rope-matrix material residue may remain after activation.

Find the Right Configuration for Your Equipment

Shop FXN-R30Shop FXN-R100

Request a Quote / Sizing ReviewRequest TDSRequest SDS

FireXNull products are supplemental localized fire suppression layers. Application suitability and performance depend on equipment and use conditions. Do not use as a substitute for code-required protection or electrical maintenance.

View full details

FIREXNULL / FXN ROPE / DISTRIBUTED COVERAGE

Flexible suppression for larger electrical cabinets

FXN Rope provides a heat-activated, distributed suppression layer inside compatible control cabinets, electrical enclosures and equipment racks. Its flexible format can be routed near multiple potential ignition locations.

No powerPassive heat response
No sensorsAutomatic activation
LocalizedApplication-specific placement
SupplementalComplements required fire protection

01 / APPLICATIONS

Where to evaluate it

  • Industrial control cabinets and MCCs
  • Switchgear and distribution enclosures
  • Telecom and server equipment cabinets

02 / PRODUCT FACTS

At a glance

  • 428°F nominal activation
  • Flexible length-based coverage
  • Magnetic-hook and supported mounting options

03 / INSTALLATION & EVALUATION

Before you install or integrate

  1. De-energize equipment and follow applicable electrical safe-work procedures.
  2. Route and secure the rope in the upper interior area using approved supports, keeping it unobstructed and away from pinch points.
  3. Record the installation date and inspect mounting and condition during scheduled maintenance.
Request technical data sheet →

04 / FREQUENTLY ASKED QUESTIONS

What to know

Where is FXN Rope installed?

The TDS specifies the upper interior of the enclosure, routed near likely ignition points and secured with appropriate mounting supports.

Does the rope need a power source?

No. It is passive and activates when sufficient heat reaches the rope.

Is the rope UL-listed for fire suppression?

No. FXN Rope is not represented as a UL-listed fire suppression product.

Does it replace sprinklers or extinguishers?

No. It is a supplemental, localized fire suppression component for eligible enclosures.

FireXNull products are supplemental, application-specific localized fire suppression solutions and do not replace code-required fire detection, fire protection, or safe electrical installation practices. Refer to the product TDS and SDS.